Contact Us:
sales@inosaki.com

VS/VE12-2N430 Cylindrical Photoelectric Sensors – SICK Sensor

$ 155.25

SKU SICK 6026222 Category

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number:6026222
Photoelectric Sensor Model:VS/VE12-2N430
OEM Spec Ref 

Features

Sensor/ detection principle Through-beam photoelectric sensor
Dimensions (W x H x D) 12 mm x 12 mm x 66.3 mm
Housing design (light emission) Cylindrical
Housing length 66.3 mm
Thread diameter (housing) Round connector M12 x 1
Sensing range max. 0 m … 5 m
Sensing range 0 m … 4 m
Focus Approx. 1.4°
Type of light Infrared light
Light source LED 1)
Light spot size (distance) Ø 100 mm (4 m)
Angle of dispersion Approx. 1.4°
Wave length 880 nm
Adjustment None
  • 1) Average service life: 100,000 h at TU = +25 °C.

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple ± 10 % 2)
Current consumption 20 mA 3)
Switching output NPN
Switching mode Light/dark switching
Switching mode selector Selectable via L/D control cable
Output current Imax. ≤ 100 mA 3)
Response time ≤ 2 ms 4)
Switching frequency 250 Hz 5)
Connection type Male connector M12, 4-pin
Circuit protection 6)

7)

8)

9)

Protection class III
Weight 36 g
Housing material Metal, Nickel-plated brass/PA
Optics material Plastic, PMMA
Enclosure rating IP67
Ambient operating temperature –25 °C … +70 °C
Ambient temperature, storage –25 °C … +70 °C
UL File No. NMFT2.E175606
  • 1) Limit values.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Signal transit time with resistive load.
  • 5) With light/dark ratio 1:1.
  • 6) A = VS connections reverse-polarity protected.
  • 7) B = inputs and output reverse-polarity protected.
  • 8) C = interference suppression.
  • 9) D = outputs overcurrent and short-circuit protected.