DFS60I-BEEC65536 – SICK Incremental Encoders

$ 764.75

SKU SICK 1112764 Category

Part Number: 1112764
Encoders Model: DFS60I-BEEC65536
OEM Spec Ref 

 

Performance

Pulses per revolution 65,536 1)
Measuring step 90°, electric/pulses per revolution
Measuring step deviation at binary number of lines ± 0.0015°
Error limits ± 0.03°

1) See maximum revolution range.

 

Interfaces

Communication interface Incremental
Communication Interface detail HTL / Push pull
Number of signal channels 6-channel
Initialization time 40 ms
Output frequency ≤ 820 kHz
Load current ≤ 30 mA
Operating current 40 mA (without load)
Power consumption ≤ 0.5 W (without load)
Load resistance ≥ 120 Ω

 

Electronics

Connection type Male connector, M12, 8-pin, radial
Supply voltage 10 … 32 V
Reference signal, number 1
Reference signal, position 90°, electric, logically gated with A and B
Reverse polarity protection
Short-circuit protection of the outputs ✔ 1)

1) Short-circuit opposite to another channel, US or GND permissable for maximum 30 s.

 

Mechanics

Mechanical design Blind hollow shaft
Shaft diameter 12 mm
Weight + 0.5 kg
Shaft material Stainless steel V2A
Flange material Stainless steel V2A
Housing material Stainless steel V2A
Start up torque 1 Ncm (+20 °C)
Operating torque 0.5 Ncm (+20 °C)
Permissible movement static ± 0.3 mm (radial)

± 0.5 mm (axial)

Permissible movement dynamic ± 0.05 mm (radial)

± 0.01 mm (axial)

Operating speed ≤ 6,000 min⁻¹ 1)
Moment of inertia of the rotor 40 gcm²
Bearing lifetime 3.6 x 10^10 revolutions
Angular acceleration ≤ 500,000 rad/s²

1) Allow for self-heating of 3.3 K per 1,000 rpm when designing the operating temperature range.

 

Ambient Data

EMC According to EN 61000-6-2 and EN 61000-6-4
Enclosure rating IP67, housing side (IEC 60529) 1)

IP67, shaft side (IEC 60529)

Permissible relative humidity 90 % (Condensation not permitted)
Operating temperature range –40 °C … +100 °C 2)

–30 °C … +100 °C 3)

Storage temperature range –40 °C … +100 °C, without package
Resistance to shocks 100 g, 6 ms (EN 60068-2-27)
Resistance to vibration 10 g, 10 Hz … 2,000 Hz (EN 60068-2-6)

1) With mating connector fitted.

2) Stationary position of the cable.