Contact Us:
sales@inosaki.com

VTF18-4N1240 Cylindrical Photoelectric Sensors – SICK Sensor

$ 82.34

SKU N/A Category

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 6012822
Photoelectric Sensor Model: VTF18-4N1240
OEM Spec Ref 

Features

Sensor/ detection principle Photoelectric proximity sensor, Background blanking
Dimensions (W x H x D) 18 mm x 18 mm x 78 mm
Housing design (light emission) Cylindrical
Housing length 78 mm
Thread diameter (housing) M18 x 1
Optical axis Axial
Sensing range max. 3 mm … 100 mm 1)
Sensing range 3 mm … 90 mm
Type of light Infrared light
Light source LED 2)
Light spot size (distance) Ø 3 mm (50 mm)
Adjustment Potentiometer, 270° (Sensing range)
  • 1) Object with 90 % reflectance (referred to standard white, DIN 5033).
  • 2) Average service life: 100,000 h at TU = +25 °C.

 

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple ± 10 % 2)
Current consumption 30 mA 3)
Switching output NPN 4)
Switching mode Light/dark switching 4)
Switching mode selector Selectable via L/D control cable
Output current Imax. ≤ 100 mA
Response time ≤ 2 ms 5)
Switching frequency 250 Hz 6)
Connection type Male connector M12, 4-pin
Circuit protection 7)

8)

9)

10)

Protection class III
Weight 120 g
Housing material Metal, Nickel-plated brass
Optics material Plastic, PMMA
Enclosure rating IP67
Special feature Focused optics
Ambient operating temperature –25 °C … +70 °C
UL File No. NMFT2.E175606
  • 1) Limit values.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Control wire open: light switching L.ON.
  • 5) Signal transit time with resistive load.
  • 6) With light/dark ratio 1:1.
  • 7) A = VS connections reverse-polarity protected.
  • 8) B = inputs and output reverse-polarity protected.
  • 9) C = interference suppression.
  • 10) D = outputs overcurrent and short-circuit protected.

Additional information

Related Products

ST 6-PE -Ground modular terminal block - 3031500 -Phoenix Contact
Festo_Proximity sensors_SMT-10M-NS-24V-E-1-Q-OE_551372 01
IDS FrameGrabber-FALCONplus Express
SICK_Miniature Photoelectric Sensors_G6_WS-GSE6-P4112
SIMATIC_ET_200SP_Analog_Output_Modules_AQ 2xU ST
Panasonic_FP0 Intelligent units
Select your currency