Contact Us:
sales@inosaki.com

W9 – WTB9-3P2261 Photoelectric Sensors – Small Photoelectric Sensors – SICK Sensor

$ 132.25

SKU N/A Category

SICK sensor one of the world’s leading producers of sensors and sensor solutions for industrial applications. SICK is a technology and market leader in Factory and Logistics Automation as well as Process Automation. The sensor range are: Laser Sensors, Cylinder Sensors, Photoelectric Sensors, Fork Sensors, Encoders, Color Sensors, Distance Sensor, Contrast Sensor, Color Sensor, Inductive Proximity Sensors, Fiber Optic Sensor with our signature range sick sensor intelligence.

Part Number: 1049047
Photoelectric Sensor Model: WTB9-3P2261
OEM Spec Ref 

Features

Device type Photoelectric sensors
Sensor/ detection principle Photoelectric proximity sensor, Background suppression
Dimensions (W x H x D) 12.2 mm x 49.8 mm x 23.6 mm
Housing design (light emission) Rectangular
Mounting hole M3
Sensing range max. 20 mm … 350 mm 1)
Sensing range 20 mm … 200 mm 2)
Type of light Visible red light
Light source PinPoint LED 3)
Light spot size (distance) Ø 4.5 mm (75 mm)
Wave length 650 nm
Adjustment Potentiometer, 5 turns
  • 1) Object with 90 % reflectance (referred to standard white, DIN 5033).
  • 2) Object with 6 % reflectance (referred to standard white, DIN 5033).
  • 3) Average service life: 100,000 h at TU = +25 °C.

 

Mechanics/electronics

Supply voltage 10 V DC … 30 V DC 1)
Ripple < 5 Vpp 2)
Current consumption 30 mA 3)
Switching output PNP 4)
Output function Complementary
Switching mode Light/dark switching 4)
Output current Imax. ≤ 100 mA 5)
Response time < 0.333 ms 6)
Switching frequency 1,500 Hz 7)
Connection type Male connector M8, 4-pin
Circuit protection 8)

9)

10)

Protection class III
Weight 13 g
Housing material Plastic, VISTAL®
Optics material Plastic, PMMA
Enclosure rating IP66

IP67

IP69K

Ambient operating temperature –40 °C … +60 °C
Ambient temperature, storage –40 °C … +75 °C
UL File No. NRKH.E181493
  • 1) Limit values when operated in short-circuit protected network: max. 8 A.
  • 2) May not exceed or fall below Uv tolerances.
  • 3) Without load.
  • 4) Q = light switching.
  • 5) At and above Tu 50 °C, a max. load current of Imax. = 50 mA is permitted.
  • 6) Signal transit time with resistive load.
  • 7) With light/dark ratio 1:1.
  • 8) A = VS connections reverse-polarity protected.
  • 9) B = inputs and output reverse-polarity protected.
  • 10) C = interference suppression.

Additional information

Related Products

Festo_Remote I-O and network interface components_CTEU-PN_2201471_1
camera-gige-ueye-cp-rev2-1
Festo_Vacuum Generators_VN-05-H-T3-PQ2-VQ2-RO1-A_532620
AFP0HXY64D2T
Computar_Monofocal Lens_M0814-MP2
Festo_Piston rod cylinders_ADN-32-50-I-P-A_536285_1